Technetium-99m sulfur colloid
Approved Use:
- In adults, to assist in the:
- localization of lymph nodes draining a primary tumor in patients with breast cancer or malignant melanoma when used with a hand-held gamma counter
- evaluation of peritoneo-venous (LeVeen) shunt patency
- In adults and pediatric patients, for imaging:
- areas of functioning reticuloendothelial cells in the liver, spleen and bone marrow
- studies of esophageal transit and, gastroesophageal reflux, and detection of pulmonary aspiration of gastric contents
- Breast cancer or malignant melanoma setting (ADULTS): 0.1 - 1 mCi SQ
- LeVeen shunt evaluation (ADULTS): 1 - 3 mCi intraperitoneal injection, or 0.3 - 1 mCi percutaneous transtubal injection
- Liver/spleen imaging (ADULTS): 1 - 8 mCi IV
- Liver/spleen imaging (PEDIATRIC): 0.015 - 0.075 mCi/kg IV
- Liver/spleen imaging (NEWBORNS): 0.20 - 0.50 mCI IV
- Bone marrow imaging (ADULTS): 3 - 12 mCi IV
- Bone marrow imaging (PEDIATRIC): 0.03 - 0.15 mCi/kg IV
- Gastroesophageal studies (ADULTS): 0.15 - 0.30 mCi PO
- Gastroesophageal studies (PEDIATRIC): 0.10 - 0.30 mCi PO or nasogastric tube
- Pulmonary aspiration studies (ADULTS): 0.30 - 0.50 mCi PO
- Pulmonary aspiration studies (PEDIATRIC): 0.10 - 0.30 mCi PO or nasogastric tube
Manufacturer: Sun Radiopharma
Package Insert
How Supplied: 5 kits per box
Each kit consists of three components:
Allergy Information
Product Website
Lymph Node Localization Summary Slides
Package Insert
How Supplied: 5 kits per box
Each kit consists of three components:
- Reaction Vial, containing, in lyophilized form, 2 mg sodium thiosulfate anhydrous, 2.3 mg edetate disodium and 18.1 mg bovine gelatin
- Solution A Vial, containing 1.8 mL 0.148 N hydrochloric acid solution
- Solution B Vial, containing 1.8 mL aqueous solution of 24.6 mg/mL sodium biphosphate anhydrous and 7.9 mg/mL sodium hydroxide
Allergy Information
Product Website
Lymph Node Localization Summary Slides
Manufacturer: Jubilant Radiopharma
Package Insert
How Supplied: 5 kits per box
Each kit consists of three components:
Package Insert
How Supplied: 5 kits per box
Each kit consists of three components:
- Reaction Vial, containing, in lyophilized form, 2 mg sodium thiosulfate anhydrous, 2.3 mg edetate disodium and 18.1 mg bovine gelatin
- Solution A Vial, containing 1.8 mL 0.148 N hydrochloric acid solution
- Solution B Vial, containing 1.8 mL aqueous solution of 24.6 mg/mL sodium biphosphate anhydrous and 7.9 mg/mL sodium hydroxide
Clinical Guidelines:
- ACR-SPR Practice Parameter for the Performance of Gastrointestinal Scintigraphy (2015)
- ACR-SPR Practice Parameter for the Performance of Liver and Spleen Scintigraphy (2015)
- EANM Practice Guidelines for Lymphoscintigraphy and Sentinel Lymph Node Biopsy in Melanoma (2015)
- EANM Practice Guidelines for Lymphoscintigraphy and Sentinel Node Localization in Gynecological Cancers (2014)
- SNMMI Procedure Standard-EANM Practice Guideline for Lymphoscintigraphy and Sentinel Node Localization in Breast Cancer (2013)
- SNMMI Procedure Standard-EANM Practice Guideline for Small-Bowel and Colon Transit 1.0 (2013)
- SNMMI Procedure Standard for Gastric Emptying 3.0 (2009)